Sydney's bus network is in the middle of one of the biggest fleet changes in its history. Depots that once held rows of diesel and gas buses are being rebuilt around chargers, switchboards and battery-electric vehicles that sit plugged in overnight. For operators, depot managers and the people who work the night shift, that change brings a fire risk with different rules from the one they trained for.
This guide looks at what Fire and Rescue NSW now expects of electric bus depots, what the incident data and overseas experience tell us, and the practical steps operators of any size can take, from metropolitan contractors to regional school bus and coach companies adding their first electric vehicles.
Why bus depots are a distinct fire setting
A bus depot concentrates a lot of stored energy in one place. Dozens, sometimes hundreds, of large battery packs are parked close together, often charging at the same time, usually overnight when fewer staff are on site. Transport for NSW's Zero Emission Buses program is converting 11 diesel and natural gas depots in Greater Sydney in its first stage, supporting 1,200 new battery-electric buses, with around 1,700 zero emission buses expected on Sydney roads by the end of 2028 (Transport for NSW, n.d.).
Buses already have a fire history that has nothing to do with batteries. The NSW Office of Transport Safety Investigations recorded 816 bus fire and thermal incident notifications between 2013 and 2022, made up of 177 fires and 639 thermal incidents, with an estimated cost of $203 million and 52 buses destroyed or significantly damaged over the decade (Office of Transport Safety Investigations, 2023). Electrical faults were the most common cause of the fires. The same report noted that further research was needed to understand the fire risks of electric batteries and hydrogen fuel cells, and that newer mitigation technologies would be needed to keep zero emission buses safe (Office of Transport Safety Investigations, 2023).
What makes an electric bus fire different
The hazard at the centre of every lithium-ion incident is thermal runaway. Fire and Rescue NSW describes it as a self-sustaining chain reaction inside a battery pack that can be set off by heat, impact, overcharging or a battery fault, whether the bus is being driven, charged or simply parked (Fire and Rescue NSW, 2026). Three features matter most in a depot:
- Gas before flame. Thermal runaway releases large volumes of toxic and flammable gas, which can lead to a fire, a toxic cloud or a gas explosion (Fire and Rescue NSW, 2026). Research reviewing battery fires in electric cars, hybrids and electric buses also describes toxic gas, jet flames and explosion as possible outcomes of battery failure (Sun et al., 2020).
- Inaccessible fuel. The burning cells sit inside a sealed pack. Suppressant applied from outside struggles to reach them, and the pack can re-ignite without enough cooling (Sun et al., 2020).
- Re-ignition over days. Fire and Rescue NSW warns that re-ignition can occur hours, days or even weeks after a fire appears to be out (Fire and Rescue NSW, 2026). AFAC gives the same warning for damaged electric vehicle batteries generally (Australasian Fire and Emergency Service Authorities Council [AFAC], 2024).
Because of this, firefighters generally take a defensive approach to a burning electric bus, protecting surrounding buses and buildings while the battery burns out (Fire and Rescue NSW, 2026). The aim of depot design is to make sure one bus stays one bus.
Lessons from overseas depot fires
Australia has the advantage of learning from depots that electrified earlier. On 30 September 2021, a fire at a Stuttgart bus depot in Germany destroyed 25 buses, including two electric buses, with damage estimated in the millions of euros. Investigators said the fire may have started while a bus was being charged, and the operator paused its electric buses while the cause was examined (Meza, 2021). An employee reportedly saw flames on top of an electric bus that was connected to a charger, although that bus had not been officially confirmed as the origin (Nedelea, 2021). Munich's transport operator took eight similar buses out of service as a precaution, and earlier depot fires in Hanover and Düsseldorf that year had also caused major losses (Meza, 2021).
The point for Australian operators is not that electric buses are uniquely dangerous. Diesel depots burn too. The lesson is that buses parked close together under one roof can turn a single-vehicle fault into a whole-fleet loss, and that charging time is a period of elevated attention.
What Fire and Rescue NSW expects of an e-bus depot
Fire and Rescue NSW has published a technical information sheet on fire safety in electric bus depots (Fire and Rescue NSW, 2026). It is guidance rather than legislation, but it signals what the fire service will look for when it is consulted on a new or converted depot. Key points include:
- Charge outside where possible. Charging bays should be outdoors in well-ventilated areas. A battery explosion inside a building is likely to cause severe structural damage.
- Cluster and separate. Buses should be parked in clusters with separation distances between them, and different bus types segregated.
- Have an isolation area. Damaged or faulty batteries and buses should be moved to an open-air isolation area away from other vehicles and buildings, and kept there until re-ignition is unlikely.
- Plan for a lot of water. Hydrant coverage should extend across the whole depot, including outdoor parking and charging, with a water supply that allows for prolonged cooling of batteries in thermal runaway. Sprinklers are recommended in maintenance and workshop buildings.
- Detect early. Automatic fire detection and CCTV are expected wherever buses or batteries may be, with flame detectors recommended for outdoor parking and charging areas.
- Shut down fast. Emergency shutdown switches should be located at the fire control centre and near each charging bay.
- Plan the response. The depot should have an emergency plan under AS 3745-2010 and an information package for firefighters, including rescue sheets for each bus model.
One instruction deserves to be repeated in every depot induction: drivers should not attempt to relocate any bus in the event of any fire (Fire and Rescue NSW, 2026). The instinct to drive a burning bus away from the others is understandable, but it puts the driver inside a vehicle that may be releasing toxic gas.
A practical checklist for depot managers
Large depot conversions are designed by engineers, but day-to-day safety still comes down to the people on site. Smaller operators, including regional school bus and coach companies, often electrify one or two vehicles at a time without a dedicated fire engineer. Either way, these steps are worth working through:
- Map your batteries. List every lithium-ion battery on site: buses, depot cars and utes, forklifts, cordless tools, radios and spare packs. Note where each one charges.
- Review where you charge. Compare your charging layout against the Fire and Rescue NSW guidance. If buses charge inside a shed, talk to your fire engineer about ventilation, separation and detection.
- Nominate an isolation spot. Agree in advance where a damaged bus or battery will go after a crash, flood or fault, and who decides when it is safe to move it back. AFAC notes that flood-damaged electric vehicles carry a risk of thermal runaway (AFAC, 2024).
- Know the warning signs. Train drivers and yard staff to report unusual smells, hissing, popping, smoke from under a bus, or battery fault alerts, and to treat them as an emergency rather than a maintenance ticket.
- Write the first five minutes down. Who isolates the charger, who calls 000, who meets the fire brigade at the gate, and where everyone assembles upwind of the smoke.
- Look after the workshop. Small batteries in tool cribs and maintenance bays are a more frequent source of fires than the buses themselves. Charge them on non-combustible surfaces away from exits, and quarantine any that are swollen or damaged.
- Brief the night shift. Most charging happens when the depot is quietest. Make sure overnight staff know the plan as well as the day crew.
Where portable equipment fits
Portable equipment will not put out a fully involved battery fire in a 12-metre bus, and no one should try. That is a job for the fire brigade, and the depot's design should buy them time. What portable equipment can do is deal with the smaller, earlier and more common incidents that happen around a depot, and protect people while they get clear. For depot operators, three items from the EV Fire Solutions range are worth considering:
- The 9L EV Fire Extinguisher for Lithium-Ion Battery Fires, suited to charging areas and workshops where staff may face an early-stage incident involving equipment or smaller batteries.
- The 8m x 6m Heavy-Duty EV Car Fire Blanket, for the electric depot cars, supervisor vehicles and utes that often share the site with the bus fleet. A blanket helps contain flame and limit spread to nearby vehicles while the brigade is on its way.
- The Premium Fire-Resistant Battery Containment Bag, for quarantining swollen or damaged tool, radio and spare batteries in the workshop until they can be disposed of safely.
Equipment works best when people know when to use it and when to walk away. Our Lithium Battery Fire Safety Awareness online course can help bring drivers, yard staff and workshop teams to a common baseline.
Safety note
If a bus, vehicle or battery is on fire, or is smoking, hissing or venting gas, do not try to move it. Get everyone out and away, stay upwind of the smoke, and call 000. Only use an extinguisher or blanket on a small, early-stage fire if it is safe to do so and you have a clear exit. Tell the fire brigade that lithium-ion batteries are involved.
References
- Australasian Fire and Emergency Service Authorities Council. (2024). Community safety messages and considerations for lithium-ion batteries (AFAC Publication No. 3100, Version 1.1). https://www.ses.nsw.gov.au/sites/default/files/document/afac_lithium-ion-batteries_2024-5-15_v1-2.pdf
- Fire and Rescue NSW. (2026). Technical information: Fire safety in electric bus depots (Version 01). https://www.fire.nsw.gov.au/__data/assets/pdf_file/0017/4328/Tech-info-sheet-Fire-safety-in-electric-bus-depots.pdf
- Meza, E. (2021, October 11). Several German cities halt use of e-buses following series of unresolved cases of fire. Clean Energy Wire. https://www.cleanenergywire.org/news/several-german-cities-halt-use-e-buses-following-series-unresolved-cases-fire
- Nedelea, A. (2021, October 13). Stuttgart bus depot fire likely started by charging electric bus. InsideEVs. https://insideevs.com/news/540391/stuttgart-bus-depot-fire-electricbus/
- Office of Transport Safety Investigations. (2023). Bus fire safety report: Bus fire and thermal incidents in NSW from 2013-2022. https://www.otsi.nsw.gov.au/sites/default/files/2023-09/Bus-Fire-Safety-Report-Bus-Fire-and-Thermal-Incidents-in-NSW-from-2013-2022.pdf
- Sun, P., Bisschop, R., Niu, H., & Huang, X. (2020). A review of battery fires in electric vehicles. Fire Technology, 56(4), 1361–1410. https://doi.org/10.1007/s10694-019-00944-3
- Transport for NSW. (n.d.). Zero emission buses: Sydney bus depot conversions. Retrieved November 23, 2026, from https://www.transport.nsw.gov.au/projects/current-projects/greater-sydney-stage-1-bus-depot-conversions